Description
SARS-CoV-2 Spike RBD Titer Assay Kit | RAS-A021 | Acro Biosystems | SARS-CoV-2 Antigen Titer Assay Kits
The unopened kit is stable for at least 1 year from the date of manufacture if stored at 2°C to 8°C, and the opened kit is stable for up to 1 month from the date of opening at 2°C to 8°C.
It is recommended not to freeze thaw more than 3 times for powder.
This product is stable under storage conditions: ● 12 months in sealed state. ● Used within 1 months after opening.
Your experiment will include 6 simple steps:
a) All reagents were returned to room temperature(20℃-25℃) before use.
b) Add your sample to the plate, take the SARS-CoV-2 Spike RBD as Control sample. The samples and Control sample are diluted by Dilution Buffer.
c) Add a diluted Secondary antibody biotin-Anti-SARS-CoV-2 Spike RBD Antibody to the plate. The Secondary antibody is diluted by Dilution Buffer.
d) Add a diluted Streptavidin-HRP to the plate.
e) Wash the plate and add TMB or other colorimetric HRP substrate.
f) Stop the substrate reaction by add diluted acid. Absorbance (OD) is calculated as the absorbance at 450 nm minus the absorbance at 650 nm to remove background prior to statistical analysis. The OD Value reflects the amount of protein bound.